What FLO means
No water flow was detected while the main pump was running.
Also shown as: FLO, depending on the model.
Likely causes
- Closed valves
- Low water
- Blocked filter
- Air trapped in the plumbing
- Heater pump not running
Safe first checks
- Make sure the circulation valves are open and the water level is high enough.
- Turn the spa off at its breaker and make sure nothing is blocking the filter.
- If air is trapped, Gecko says to start the pump and slowly loosen a union nut to let the air out, then tighten it.
When to stop
Gecko lists a minimum flow of 18 GPM. In.flo cable, configuration and heater wiring checks are tech steps.
Parts that may help
Only order a part once the checks above point to it, and match the part number to your model.
Checked against: Gecko Alliance Y-series and in.xe troubleshooting guide (9919-101313-D, July 2023). Codes can differ by model and year, so confirm with your owner's manual.