Smell gas or hear a CO alarm? Leave now and call 911 or your gas utility from outside.

Mitsubishi Electric mini-split error code

Mitsubishi Electric mini-split code P5 / PA / P4: Drain pump error / float switch

Mitsubishi Electric Mr. Slim indoor units with a drain pump

What P5 means

A drain problem: P5 is a drain pump error, PA is a forced compressor stop due to a water leakage abnormality, and P4 means the float switch connector is open.

Also shown as: PA, P4, 4 blinks, 5 blinks, depending on the model.

Likely causes

  • Clogged condensate drain or pump
  • Drain pump failure
  • Float switch disconnected

Safe first checks

  1. Turn the system off. Look for water dripping from the indoor unit or a full condensate pump reservoir.
  2. If a condensate pump is plugged in separately, make sure it has power and its outlet tube isn't clogged.

When to stop

Drain pump and float switch repairs inside the unit are for an HVAC technician.

Checked against: Mitsubishi Electric, Mr. Slim indoor/outdoor unit malfunction-diagnosis check codes (2024-11-18). Codes can differ by model and year, so confirm with your owner's manual.