Pentair pool heater error code

Pentair pool heater code ERR HLS / HLS: High limit switch open

Pentair MasterTemp heaters

What ERR HLS means

The high temperature limit switch opened: water after the first pass through the heat exchanger is over 135°F. It clears when the water drops below 135°F.

Also shown as: HLS, depending on the model.

Likely causes

  • Low water flow
  • Dirty filter
  • Limit switch fault

Safe first checks

  1. Check flow first: pump running, baskets empty, filter clean, valves open.
  2. Let the heater cool and the code clear.

When to stop

Repeated high-limit trips with good flow need a qualified tech. Don't bypass limit switches.

Parts that may help

Only order a part once the checks above point to it, and match the part number to your model.

Checked against: Pentair MasterTemp heater installation and user's guide (Table 8: error and fault codes). Codes can differ by model and year, so confirm with your owner's manual.