Smell gas or hear a CO alarm? Leave now and call 911 or your gas utility from outside.

Pentair pool heater error code

Pentair pool heater code ERR PS / PS: Water pressure switch open (no flow)

Pentair MasterTemp gas pool and spa heaters

What ERR PS means

The water pressure switch is open because there's no water flow through the heater. It clears once flow is established.

Also shown as: PS, depending on the model.

Likely causes

  • Pump off or set too slow
  • Dirty filter
  • Full skimmer or pump basket
  • Closed or misset valves
  • Low pool water

Safe first checks

  1. Make sure the pump is running and, on a variable-speed pump, at a high enough speed.
  2. Turn the pump off at the breaker, then empty the skimmer and pump baskets and clean the filter (release filter pressure first).
  3. Check that valves to the heater are open and the water level is mid-skimmer.

When to stop

Pentair warns never to bypass the pressure switch. If flow is good and the code stays, have a qualified tech test the switch.

Parts that may help

Only order a part once the checks above point to it, and match the part number to your model.

Checked against: Pentair MasterTemp heater installation and user's guide (Table 8: error and fault codes). Codes can differ by model and year, so confirm with your owner's manual.